To be allowed to display the ENERGY STAR symbol, products must meet or exceed technical specifications designed to ensure that they are among the most energy efficient in the marketplace. Minimum requirements vary from one category to another, but typically an ENERGY STAR model must be from 10 to 50 percent more efficient than a conventional model. Sizing ConsiderationsUnlike the outside air, the temperature of the ground remains fairly constant. As a result, the output of an EES varies little throughout the winter. Since the EES's output is relatively constant, it can be designed to meet almost all the space heating requirement – with enough capacity left to provide water heating as an "extra." As with air-source heat pump systems, it is generally not a good idea to size an EES to provide all of the heat required by a house. For maximum cost-effectiveness, an EES should be sized to meet 60 to 70 percent of the total maximum "demand load" (the total space heating and water heating requirement). The occasional peak heating load during severe weather conditions can be met by a supplementary heating system. A system sized in this way will in fact supply about 95 percent of the total energy used for space heating and water heating. EESs with variable speed or capacity are available in two-speed compressor configurations. This type of system can meet all cooling loads and most heating loads on low speed, with high speed required only for high heating loads. A variety of sizes of EESs are available to suit the Canadian climate. Units range in size from 7 kW to 35 kW (24 000 to 120 000 Btu/h), and include domestic hot water (DHW) options. Design ConsiderationsUnlike air-source heat pumps, EESs require that a well or loop system be designed to collect and dissipate heat underground. Open SystemsAs noted, an open system (see Figure 11) uses ground water from a conventional well as a heat source. The ground water is pumped into the heat pump unit, where heat is extracted. Then, the "used" water is released in a stream, pond, ditch, drainage tile, river or lake. This process is often referred to as the "open discharge" method. (This may not be acceptable in your area. Check with local authorities.) Figure 11: Open System Using Groundwater From a Well as a Heat Source
Another way to release the used water is through a rejection well, which is a second well that returns the water to the ground. A rejection well must have enough capacity to dispose of all the water passed through the heat pump, and should be installed by a qualified well driller. If you have an extra existing well, your heat pump contractor should have a well driller ensure that it is suitable for use as a rejection well. Regardless of the approach used, the system should be designed to prevent any environmental damage. The heat pump simply removes or adds heat to the water; no pollutants are added. The only change in the water returned to the environment is a slight increase or decrease in temperature. The size of the heat pump unit and the manufacturer's specifications will determine the amount of water that is needed for an open system. The water requirement for a specific model of heat pump is usually expressed in litres per second (L/s) and is listed in the specifications for that unit. A heat pump of 10-kW (34 000-Btu/h) capacity will use 0.45 to 0.75 L/s while operating. Your well and pump combination should be large enough to supply the water needed by the heat pump in addition to your domestic water requirements. You may need to enlarge your pressure tank or modify your plumbing to supply adequate water to the heat pump. Poor water quality can cause serious problems in open systems. You should not use water from a spring, pond, river or lake as a source for your heat pump system unless it has been proven to be free of excessive particles and organic matter, and warm enough throughout the year (typically over 5°C) to avoid freeze-up of the heat exchanger. Particles and other matter can clog a heat pump system and make it inoperable in a short period of time. You should also have your water tested for acidity, hardness and iron content before installing a heat pump. Your contractor or equipment manufacturer can tell you what level of water quality is acceptable and under what circumstances special heat-exchanger materials may be required. Installation of an open system is often subject to local zoning laws or licensing requirements. Check with local authorities to determine if restrictions apply in your area. Closed-Loop SystemsA closed-loop system draws heat from the ground itself, using a continuous loop of special buried plastic pipe. Copper tubing is used in the case of DX systems. The pipe is connected to the indoor heat pump to form a sealed underground loop through which an antifreeze solution or refrigerant is circulated. While an open system drains water from a well, a closed-loop system recirculates its heat transfer solution in pressurized pipe. The pipe is placed in one of two types of arrangements: vertical or horizontal. A vertical closed-loop arrangement (see Figure 12) is an appropriate choice for most suburban homes, where lot space is restricted. Piping is inserted into bored holes that are 150 mm (6 in.) in diameter, to a depth of 18 to 60 m (60 to 200 ft.), depending on soil conditions and the size of the system. Usually, about 80 to 110 m (270 to 350 ft.) of piping is needed for every ton (3.5 kW or 12 000 Btu/h) of heat pump capacity. U-shaped loops of pipe are inserted in the holes. DX systems can have smaller diameter holes, which can lower drilling costs. Figure 12: Closed-Loop, Single U-Bend Vertical Configuration
The horizontal arrangement (see Figure 13) is more common in rural areas, where properties are larger. The pipe is placed in trenches normally 1.0 to 1.8 m (3 to 6 ft.) deep, depending on the number of pipes in a trench. Generally, 120 to 180 m (400 to 600 ft.) of pipe are required per ton of heat pump capacity. For example, a well-insulated, 185 m2 (2000 sq. ft.) home would probably need a three-ton system with 360 to 540 m (1200 to 1800 ft.) of pipe. The most common horizontal heat exchanger design is two pipes placed side-by-side in the same trench. Another heat exchanger sometimes used where area is limited is a “spiral” – which describes its shape. Other horizontal loop designs use four or six pipes in each trench, if land area is limited. Figure 13: Closed-Loop, Single Layer Horizontal Configuration
Regardless of the arrangement you choose, all piping for antifreeze solution systems must be at least series 100 polyethylene or polybutylene with thermally fused joints (as opposed to barbed fittings, clamps or glued joints), to ensure leak-free connections for the life of the piping. Properly installed, these pipes will last anywhere from 25 to 75 years. They are unaffected by chemicals found in soil and have good heat-conducting properties. The antifreeze solution must be acceptable to local environmental officials. DX systems use refrigeration-grade copper tubing. Neither vertical nor horizontal loops have an adverse impact on the landscape as long as the vertical boreholes and trenches are properly backfilled and tamped (packed down firmly). Horizontal loop installations use trenches anywhere from 150 to 600 mm (6 to 24 in.) wide. This leaves bare areas that can be restored with grass seed or sod. Vertical loops require little space and result in minimal lawn damage. It is important that horizontal and vertical loops be installed by a qualified contractor. Plastic piping must be thermally fused, and there must be good earth-to-pipe contact to ensure good heat transfer, such as that achieved by Tremie-grouting of boreholes. The latter is particularly important for vertical heat-exchanger systems. Improper installation may result in less than optimum heat pump performance. Installation ConsiderationsAs with air-source heat pump systems, EESs must be designed and installed by qualified contractors. Consult a local heat pump contractor to design, install and service your equipment to ensure efficient and reliable operation; also, be sure that all manufacturers' instructions are followed carefully. All installations should meet the requirements of CSA C448, an installation standard set by the Canadian Standards Association. The total installed cost of earth-energy systems varies according to site-specific conditions, but can be up to twice the cost of a gas, electric or oil furnace with add-on air conditioning. The total installed costs of open or ground water EESs can be less; the extra cost is due to ground collectors, whether they are open or closed-loop. Ductwork must be installed in homes without an existing air distribution system. The difficulty of installing ductwork will vary, and should be assessed by a contractor. Installation costs vary depending on the type of ground collector and the equipment specifications. To be economically attractive, the incremental costs of a typical installation should be recovered through energy cost savings within five years. Check with your electric utility to assess the benefits of investing in an earth-energy system. Sometimes a low-cost financing plan or incentive is offered for approved installations. Major Benefits of Earth-Energy SystemsEfficiencyIn Canada, where air temperatures can go below –30°C, and where winter ground temperatures are generally in the range of –2°C to 4°C, earth-energy systems have a coefficient of performance (COP) of between 2.5 and 3.8. The HSPFs in Figures 14 and 15 were calculated using a procedure very similar to that used for air-source heat pumps, but taking into account industry-sizing practice and regional ground water temperatures across Canada. Since earth-energy heat systems have both COP and EER standard performance ratings, it was necessary to calculate heating seasonal performance to compare operating costs with those of air-source heat pumps. A ground water EES installation in southern Canada will have a heating seasonal performance factor (HSPF) of between 10.7 and 12.8, compared with an HSPF of 3.4 for electrical-resistance heating. Similarly, a closed-loop EES in southern Canada will have an HSPF of between 9.2 and 11.0, with the higher value achieved by the most efficient closed-loop heat pump available. Figure 14 shows the HSPFs of ground water earth energy systems operating in different climatic regions in Canada, while Figure 15 shows the same for closed-loop EESs. Energy SavingsEarth-energy systems will reduce your heating and cooling costs substantially. Energy-cost savings compared with electric furnaces are around 65 percent. On average, an EES will yield savings that are about 40 percent more than would be provided by an air-source heat pump. This is due to the fact that underground temperatures are higher in winter than air temperatures. As a result, an EES can provide more heat over the course of the winter than an air-source heat pump. Figure 14: Heating Seasonal Performance Factors (HSPFs) for Ground Water or Open System EESs in Canada (left to right)
Actual energy savings will vary depending on the local climate, the efficiency of the existing heating system, the costs of fuel and electricity, the size of the heat pump installed, and its coefficient of performance at CSA rating conditions. Later in this booklet, heating energy-cost comparisons will be made between earth-energy systems and electric heating systems, as well as air-source heat pumps. Domestic Hot Water HeatingEESs also provide savings in domestic hot water costs. Some have a desuperheater that uses some of the heat collected to preheat hot water; newer designs can automatically switch over to heat hot water on demand. These features can reduce your water heating bill by 25 to 50 percent. MaintenanceEESs require little maintenance on your part. Required maintenance should be carried out by a competent service contractor, who should inspect your unit once a year.
Service contracts are similar to those for oil and gas furnaces. Operating CostsThe operating costs of an earth-energy system are usually considerably lower than those of other heating systems, because of the savings in fuel. Qualified heat pump installers should be able to give you information on how much However, the relative savings will depend on whether you are currently using electricity, oil or natural gas, and on the relative costs of different energy sources in your area. By running a heat pump, you will use less gas or oil, but more electricity. If you live in an area where electricity is expensive, your operating costs may be higher. The payback on an investment in an earth-energy system may be anywhere up to a decade or more. Later in this booklet, operating cost estimates are provided for EESs. Life Expectancy and WarrantiesEESs have a life expectancy of about 20 to 25 years. This is higher than for air-source heat pumps because the compressor has less thermal and mechanical stress, and is protected from the environment. Most ground-source heat pump units are covered by a one-year warranty on parts and labour, and some manufacturers offer extended warranty programs. However, warranties vary between manufacturers, so be sure to check the fine print. Previous | Table of Contents | Next Source: Natural Resouces Canada (NRCan) Office of Energy Efficiency
|
|||||||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||||||